Quality is our main goal

Without VAG, water would not be supplied and distributed the way it is today. Wherever water is treated, moved, stored and distributed, VAG's gate valves and butterfly valves, plunger valves and hollow-jet discharge valves, control valves and hydrants play an important role.

 

There is barely a water, pump or wastewater treatment plant that does not use a VAG valve. Durability and decades of operational reliability matter. Repairing or replacing valves that often weigh several tons, such as those used in dams, is very costly. The supply and distribution of water and the treatment of wastewater are very demanding operations. Valves must be able to withstand high water pressures and extreme temperature and weather conditions. Whether they are used in a desert or a tropical climate, the material must suit the environment. We know from our customers that our valves work reliably for up to fifty years. In fact, some of our valves have been working for more than one hundred years!

 

Coating testing

Coating thickness

Magnetic inductive test to determine the thickness of coatings or corrosion-inhibiting coating agents.

In the picture: Test according to GSK guidelines (Quality Association for the Heavy Duty Corrosion Protection of Powder Coated Valves and Fittings) minimum coat thickness > 250 µm.

Schichtdicke

Click to Zoom

   

Adhesion testing

The pull-off test (DIN EN 24624) is used to test how well the coating is bonded to the raw material. Minimum adhesion > 12 N/mm2.

Haftfestigkeitsprüfung

Click to Zoom

   

Impact testing

A pendulum that falls through a fixed distance is used for impact testing. The pendulum hits the coated surface with an energy of 5 Nm. The coating may neither crack nor peel.

Schlagbeständigkeit

   

Porosity testing

 

Porositätsprüfung

Click to Zoom

   

Infiltration testing

The cathodic infiltration test is a corrosion test according to GSK guidelines and DIN 30677 that is carried out over a test period of 30 days at 23 °C. A defect is created on the coated surface of the test specimen, which is subjected to cathodic polarisation in a sodium chloride solution for the entire test period.

Unterwanderungsprüfung

Click to Zoom

   

Pressure, leak and function testing

These pictures show the tests our valves are submitted to and the test benches used. Whether tested with water or air, all of our valves are submitted to pressure, leak and function tests.

   

Test bench butterfly valves < = DN 600

Prüfstand Absperrklappen   Prüfstand Absperrklappen

Click to Zoom

   

Test bench butterfly valves > DN 600

Prüfstand Absperrklappen  Prüfstand Absperrklappen

Click to Zoom

   

Test bench gate valve

Prüfstand Schieber  Prüfstand Schieber

Click to Zoom

   

AWWA Proof-of-design Test

This proof-of-design test is a durability test according to AWWA C 504-87 with 1,000 load alternations against one-sided pressure. (AWWA = American Water Works Association).

AWWA Proof of Design Test  AWWA Proof of Design Test

AWWA Proof of Design Test  AWWA Proof of Design Test

Click to Zoom

   

 

 

News    Company    Products    Service    Support    References    Career    Contact